Hotline
+86 1879621976360 seconds of manual response
Give technical advice within 30 minutes
24-hour free design
Huachen Transformer 2 sets power transformer to Thailand
2020-03-17Huachen 16 sets power transformer export to Mongolia
2018-07-05Leaders of xuzhou municipal government visited Huachen transformer
2018-06-08Huachen Power Transformer Shipping to Mongolia, Mining project.
2018-04-05Huachen Sales Service and Products Training
2018-03-282018 Dubai Middle East International Power New Energy Exhibition
2018-03-19Tel/Fax:+86-0516-69687778
Phone:+86-18796219763
E-mail:sales@hcbyq.com
Fax:+86-0516-82300676
Address:Tongshan Economic Development Zone Industrial Park , No. 2 Qianjiang Road, Xuzhou, Jiangsu Province,China
Product overview
35 kv oil-immersed power transformer is advanced in designing, make great improvement on the material and structure .High and low voltage clamp with steel belt or and side beam taut, form a strong frame structure, strengthen the core clamping force and tolerance transportation capacity. Anti-short circuit ability is strong, beautiful appearance, reliable operation, low loss, low noise, reach the advanced level of the same products abroad. The SZ11-8000/35 one-time through the national transformer prototype testing center for sudden short circuit test, high and low voltage coil set longitudinal oil way is good for heat dissipation, can greatly reduce the copper oil temperature difference and the hot spot temperature rise within the coil.
Execution standard:
GB 1094.1 2 general electric power transformer, power transformer temperature rise,
GB 1094.3 "level of power transformer insulation and insulation test"
GB 1094.5 the ability to withstand short-circuit power transformer
GB/T 6451 "three-phase oil-immersed power transformer technical parameters and requirements"
GB/T 15164 "guidelines for the oil-immersed power transformer load
IEC76 "power transformer"
GB 2536 "transformer oil"
800 kva ~ 31500 kva three-phase double-winding and excitation surge of power transformer:
Type | Rated capacity | Connection symbol | Voltage combination | No-load losses | Load losses | No- load current | Short-circuit impedance | ||
H.V | Tapping range | L.V | |||||||
S11-630 | 630 | Yd11 | 35 | ±5% | 3.15 6.3 10.5 | 190 | 710 | 2.4 | 4.0 |
S11-800 | 800 | 270 | 1000 | 2.4 | |||||
S11-1000 | 1000 | 370 | 1380 | 1.8 | |||||
S11-1250 | 1250 | 400 | 1570 | 1.8 | |||||
S11-1600 | 1600 | 470 | 1850 | 1.6 | |||||
S11-2000 | 2000 | 550 | 2130 | 1.6 | |||||
S11-2500 | 2500 | 630 | 2530 | 1.4 | |||||
S11-3150 | 3150 | 33~38.5 | ±5% | 3.15 6.3 10.5 | 720 | 2760 | 1.4 | ||
S11-4000 | 4000 | 880 | 3470 | 1.2 | |||||
S11-5000 | 5000 | 980 | 3990 | 1.2 | |||||
S11-6300 | 6300 | 1160 | 4880 | 1.2 | |||||
S11-8000 | 8000 | YNd11 | 33~38.5 | ±5% ±2*2.5% | 3.15 3.3 6.3 6.6 10.5 11 | 1350 | 5880 | 1.0 | |
S11-10000 | 10000 | 1300 | 5960 | 1.0 | 6.0 | ||||
S11-12500 | 12500 | 1520 | 6960 | 1.0 | |||||
S11-16000 | 16000 | 1770 | 1830 | 1.0 | |||||
S11-20000 | 20000 | 2090 | 9690 | 1.0 | |||||
S11-25000 | 25000 | 2450 | 11730 | 1.0 | |||||
S11-31500 | 31500 | 3050 | 14450 | 0.8 |
Note 1: transformer with 6300KVA or less rated capacity can provide products whose high-voltage tapping range is ±2×2.5%.
Note 2: 10.5KV and 11KV transformer lower than low voltage can provide products with connection symbol of Dyn11.
Note 3: transformer with 3150KVA or more rated capacity has the greatest tapping current on -5% tapping position.
2000 kva ~ 200000 kva three-phase load power transformer with double winding
Type | Rated capacity | Connection symbol | Voltage combination | No-load losses | Load losses | No- load current | Short-circuit impedance | ||
H.V | Tapping range | L.V | |||||||
SZ11-2000 | 630 | Yd11 | 35 | ±3*2.5% | 6.3 10.5 | 190 | 710 | 2.4 | 4.0 |
SZ11-2500 | 800 | 270 | 1000 | 2.4 | |||||
SZ11-3150 | 1000 | 370 | 1380 | 1.8 | |||||
SZ11-4000 | 1250 | 33~38.5 | ±3*2.5% | 6.3 10.5 | 400 | 1570 | 1.8 | ||
SZ11-5000 | 1600 | 470 | 1850 | 1.6 | |||||
SZ11-6300 | 2000 | 550 | 2130 | 1.6 | |||||
SZ11-8000 | 8000 | YNd11 | 33~38.5 | ±3*2.5% | 6.3 6.6 10.5 11 | 1350 | 5880 | 1.0 | |
SZ11-10000 | 10000 | 1300 | 5960 | 1.0 | 6.0 | ||||
SZ11-12500 | 12500 | 1520 | 6960 | 1.0 | |||||
SZ11-16000 | 16000 | 1770 | 1830 | 1.0 | |||||
SZ11-20000 | 20000 | 2090 | 9690 | 1.0 |
Note 1: for low voltage of 10.5 kV and 11 kV transformer, can provide connection group labeled Dyn11 products.
Note 2: the maximum current points of by 7.5% points.
The parameters of the specific information send email to: info@hcbyq.com or online consulting.
Copyights © 2019 All Rights Reserved Jiangsu Huachen Transformer Co., Ltd.
All rights reserved:Jiangsu Huachen Transformer Co., Ltd.
Phone
To be sales agent
+86 18796219763
sales@hcbyq.com
+8613624197312
008613624197312
sales@hcbyq.com